Voltage Amp/H Length Width Height Weight
12 Volts 12 AH 5.95" 3.86" 3.74" 9.68 lb


Battery Type
12V, 12 Amp Hour
20hour rate (600mA) 12Ah
10hour rate (1.12A) 11.2Ah
5hour rate (2.04A) 10.2Ah
1hour rate (7.54A) 7.54Ah
15min rate (24A) 6.0Ah
Length 151mm (5.95in)
Width 98mm (3.86in)
Height 95mm (3.74in)
Total Height 101mm (3.98in)
Approx Weight
Self Discharge  
Maximum Discharge Current for 30 seconds: 240A
Maximum Discharge Current for 5 seconds: 480A
Operating Temp
Charge 0°c(32°f) to 40°c (104°f)
Discharge -15°c(5°f) to 50°c (122°f)
Storage -15°c(5°f) to 40°c (104°f)
Internal Resistance
(1KHz) 13 mΩ
Container Material
F1 or F2


How to tell the difference between "Fast-on" terminals
F2 Fast-On Connectors F1 Fast-On Connectors F2 Fast-On Connectors


Compatible UPS Units - Battery Cross Reference
Brand Model Qty Per UPS
Conext 900 AVR 1
Deltec PRA 1000 2 or 4
Deltec PRC 1000 1 or 2
Deltec PRM 700 1
Fenton PowerPal L1000 2
Fenton PowerPal L1000X 2
Fenton PowerPal L1400 3
Fenton PowerPal L1400X 3
NCR 4070-0700-7194S (700VA) 1
OptiUPS 1000ES 2
OptiUPS 1000PS 2
OptiUPS 1400E 2
OptiUPS 650E 1
OptiUPS 650ES 1
Parasystem MBK 300 2
Parasystem MPK 320 2
Parasystem PRO 1000 2
Parasystem PRO 2200R 4
Parasystem PRO 700 1
Unisys UP910 2


  • Lead alloy with low calcium minimizes gassing and extends life of grid.
  • Through unique active material recipes, plates after undergoing curing and tank formation provide outstanding energy density and ensure the quality of the battery.
  • Using brass coated lead alloy battery terminals minimizes impedance of connecting cells inside.
  • Case made of ABS resin and cells kept under internal pressure protects from outer shock or impact.
  • Micro-porous AGM separator completely absorbs and retains electrolyte under the pressured cell design.
  • Electrolyte sufficiently serves for electrochemical reactions in battery but never spills.
  • Battery cases are sealed in epoxy and cells are covered with vents to avoid cell contamination with the atmosphere and serve for internal oxygen reaction.
  • With very little gas evolution, the water loss is minimized and service life is extended. Excess pressure and gas will be released which ensures safety.
  • Vent design is certificated by UL.


  • UPS
  • Communications
  • Lighting
  • Security & Alarm
  • Medical Equipment
  • Remote Monitoring
  • Solar Energy Station
  • Golf Carts
  • Wheelchairs
  • Motorcycles
  • Scooters
  • Riding Mowers
  • Snowmobiles
  • Water Sports